York chiller model number nomenclature pdf

York yk chillers are manufactured to the highest design. Short description carrier, commercial aircooled condensing unit. R 0715 rpl 552355 page 5 serial number nomenclature serial number 1995 current 5 5a 12345 00 factory 5 staunton,va serial number year and month of manufacture. Smart purge is included to eliminate the need for time consuming manual purging of the chiller system.

April 2010 ssprc030en split system condensing units and remote chiller evaporators 20 to 120 tons 50 and 60 hz r410a catalog. York, recippak liquid chiller air cooledreciprocating hermetic. Product aquasnap data 30rb080390 aircooled chillers with. The york amichi series is a nocompromise solution for a. It identifies the selections of variable unit features required when ordering.

Short description trane,standard cooling only coil 4tt unit nomenclature. This allinone package is a true plug and play system that provides superb efficiency. Model ylaa aircooled scroll compressor liquid chillers. Basic unit ppurchased basic unit a 1971 a 1992 smfg. Model ylaa aircooled scroll compressor liquid chillers style b. Daikin mcquay path nder air cooled chiller screw compressor 2. Yk style g centrigual liquid chiller engineering guide. Model yr twinscrew compressor liquid chillers design level c 200 through 430 tons 60 hz. Style a magnetic bearing centrifugal chiller engineering guide. Ypal rooftop units single package simplicity elite controller with hfc410a refrigerant form yk100. Model agz 026bthrough agz b twocircuit chiller 4fan model illustrated model agz 010a through agz 034a, single circuit chiller cover pictures. Smarter buildings the verasys plugandplay controls system integrates heating, ventilation, airconditioning and refrigeration hvacr equipment and controls without any.

Crn canadian registration number emm energy management module gfico ground fault interrupting convenience outlet. Please note that lookup by sales order and purchase order currently only applies to products produced 2014 and earlier. Product aquaedge 19xr highefficiency, semihermetic. Minimize the total cost of ownership for your air conditioning application with our ycal aircooled scroll chiller. Please refer to the optivew control center operators manual for a complete. To find the year of manufacture you have to combine the 2nd digits with the 4th digits. Diffuser position is not only based on inlet guide vane igv position, but also on lift. Model number nomenclature cooling capacity features. Question posted by francisco the building engineer on may 3, 2011 refer to the manufacturers website for their hvac nomenclature of the model number and serial numbers and how those numbers correspond to the tonnage and other technical data. York chillers have been tested and certified by airconditioning. Nomenclature the model number denotes the following characteristics of the unit.

The york yk chillers, manufactured by johnson controls, offer a complete. Serial number the unit serial number provides the specific chiller identity. Assumes all customer connections are on the same end of the chiller. Model number nomenclature 420 410 210 210 390 380 210 190 360 350 190 190170 330 325 170 170 315 300 210 110 290 280 190 110 270 260 170 100 255 240 150 100 245 230 150 090 230 220 150 080 210 200 190 180 170 160 150 145 125 110 110 100 100 90 90 80 80 70 70 60 60 50 50 section b unit 30gtn. Aquaforce 30xa chillers were designed from the ground up to meet the efficiency demands of today and the future by providing premium aircooled chiller packages for contractors, consulting engineers and building. To determine the correct replacement part, locate the item on drawing figure and refer to the parts list for the part number, description and quantity. They are completely selfcontained and are designed for outdoor roof or ground level installation. Doublewall available on zj and zr units only a std. Product 30hk,hl,hw data reciprocating liquid chillers 5060. Always provide this serial number when calling for service or during parts identification 2.

A new 0809 rpl 700014100 page 4 nomenclature aws 300 a d s 27 unit model number dataplate unit type. I took out a nice used york stellar series the other day to reinstall in a good friends house. Designed for maximum efficiency in the real world where 99% of the cooling season is spent in offdesign conditions. Daikin applied unit model number index unit model number index rev. Technical guide description r410a johnson controls. Carrier has led the development of centrifugal chiller, including the invention of centrifugal chiller in 1922, manufacture of the first centrifugal chiller with cooling capacity of 10,000 rt in 1972, and introduction of nonozonedepleting, chlorinefree refrigerant hfc4a in 1996. Aircooled scroll chillers style c, ton, 46456 kw, 60 hz. Well i got it installed, along with a new edge carrier stat, rewired the ah for aa heat pump, and then i thought i dont know what refrigerant it is. This unit is shipped as a single factory assembled, piped, wired and nitrogen or refrigerant charged package form 1 shipment. The upper unit is a model agz 034a, 34 ton chiller. Split system condensing units and remote chiller evaporators.

The control center is a factory mounted, wired and tested stateoftheart microprocessor based control system for hcfc123 centrifugal chillers. Packaged liquid chillers aircooled reciprocating hermetic form 150. The model number denotes the following characteristics of the unit. The chiller consists of an open motor mounted to a compressor with integral speed in creas ing gears condenser, cooler and vari able. Click the pdf file below to view information on the york equipment. Controls chiller replacement parts by part numbers, descriptions, quantities and drawing figures. Product 30hk,hl,hw data reciprocating liquid chillers 5060 hz. Low side item month b 1972 b 1993 tpurchased low side item a jan. It is commonly found in the first three digits sometimes and btus, sometimes as tons. Technical guide guide pendent economizer designs are used on side and down disdescription ashrae 90. Model ys rotary screw liquid chillers design level e 00202vip 100 thru 675 tons 315 thru 2375 kw r22 and r4a. Four digit unit number e 410a 0360 s e york chiller 50380415350 50 nomenclature the model number denotes the following characteristics of the unit. Operation maintenance water cooled centravac with ch530. The lower unit is a model agz b, ton chiller with the end protective guard removed in order to view the unit interior.

All warranty claims must specify the unit model, serial number and order number. The york model yt millennium chiller is commonly ap plied to large air conditioning systems, but may be used on other applications. Product and serial number nomenclature virginia air. York offers the largest selection of absorption, air and watercooled chillers and condensing units in the industry. View and download york ycal0014 user manual online. The ability to operate with variable flow also allows building owners to realize even greater overall system energy savings in the chilled water pumping system of up to 85%, and not just at the chiller. When the york ys chiller operates in the thermal storage control mode, the unit will. Of model number nomenclature rb 190 8 legend refer to the unit sizes and modular combinations table below. Aws air cooled screw compressor chiller nominal tonnage ex. Ductless and vrf systems a modular design and large variety of system options help make york ductless minisplit and variablerefrigerant flow vrf systems the best choice for challenging installations. York water cooled chiller model ycwj ycrj 45 to 99 style a. Johnson controls can handle many challenges with its. Ss drain pan configuration options not required for all units.

Model ycal style e aircooled scroll compressor liquid. Yr td td t0 46 c s model evaporator code design level power supply. York serial numbers id from history to october 2004 x x x x 9 9 9 9 9 9 6 digits sequenced numbers type of item mmfg. The labeltag has faded all i have on file is the model number and the serial number, make. The aquaedge chiller with diffuser control enabled available on compressor frame sizes 4 and 5 improves the chillers part load efficiency by increasing the diffuser opening.

Model yvwa variablespeed, watercooled screw compressor chillers. Product and serial number nomenclature virginiaair. A large number of standard heat exchangers and pass arrangements are. Can you tell the date of manufacture by reading the serial number.

York hvac had two different serial numbers for 1971 through 2004 and 2005 through the present day. Ycazycaj style a air cooled reciprocating hermetic. Serial number chart us air conditioning distributors. This aircooled chiller uses scroll compressor technology and is a reliable, completely selfcontained unit that is designed for easy, lowcost outdoor installation. Yk centrifugal chiller 2503,000 tr 88010,550 kw from schools to data centers, this watercooled, centrifugal chiller delivers flexibility, performance and efficiency to any facility. York equipment nomenclature chart fca equipmentasset. Liquid temperature reset via a johnson controls isn. A z in position 11 indicates a special order machine.

Service model number the service model represents the unit as built for service purposes. Leaving temperature set point can be set to within 0. E heat pum p, o utdoor u nit f s ingle p iece a ir h andler. In the search box below, enter a unit serial number and find it. Through the seventies date of manufacture information is found as a number and a letter in the serial number where the number is the. Trane model number nomenclature building intelligence center.

1511 774 316 119 1004 1136 49 1112 1476 233 200 646 675 1498 225 840 824 602 1129 1444 1551 184 259 714 1410 1521 344 138 129 529 293 773 668 819 446 923 1431 54 761 1295 138 1033 157 297 812 290